Our Services
Protecting you and your business:
DELTA ELECTRO SYSTEM & CONTROLS puts safety at the heart of your process, every
time and all time.
Safety is at the core of everything we do here at DELTA ELECTRO SYSTEM &
CONTROLS. We have the capacity to design and build programmable safety systems
for already existing control systems. Needless to say, all of this comes with
the required safety documentation. So then, what control technologies do DELTA
ELECTRO SYSTEM & CONTROLS provide machine safety for? Well, the answer to that
is – pretty much all of them! This includes machine vision, motion control, PLC
systems and all of our process engineering offerings in general. Regardless of
the size of company, project or even industry sector, we make safety our
priority – starting with designers’ risk assessments and ending with final
safety documentation, we will make sure that your process, staff and business
are protected by systems at as low a risk as possible. Safety comes as standard.
All of our systems are designed to be as safe as they are effective. Of course,
we can also provide things such as light guards, safety scanners and safety
perimeter fencing. We offer consultation and guidance with the POWER health and
safety guidelines, determining the performance and safety integrity level of
your system.
Painting Aspect
7 and 10 – TANK PROCESS TREATMENT PLANT
- The Complete enclosure transfer to treatment Plant for processing the Enclosure which are made to ready for painting.
- POWDER COATED PAINT BOOTH :
Immediately on Completion of Treatment Procedure, the enclosure are properly cleaned then transfer to the Heat Chamber to evaporate any liquid particle in the corner of the Enclosure. Further the enclosure taken to paint Booth for Powder Coating paints by maintaining the Electro-Static Charging System. In the Enclosure shall be (-) Ve charged and the paint Powder shall be (+) Ve charged through Powder Coating Machine to minimize the dent surface, then the enclosure has been taken to heat chamber for drying up the paints at 20000 C for 30 minutes to keeping the enclosure proper surface with adequate hardness of paints and avoiding scratching mark during assembly time. Ultimate all the above processes are controlled by trained and professionally qualified QA team thereby the quality of the job will be acceptable by our ultimate Customer.
BUS BARS
- Vertical busbar extended into each section to supply power to each individual section.
- Horizontal bus-bar systems with FRP supports for main power distribution at the top. Bus-bar shall be of uniform cross section throughout the length.
- Bus-bars are fabricated from high conductivity aluminum alloy or electrolytic grade copper.
- Proper color coating are provided on bus-bars for providing phase (RYB & N) identification in line with requirement as per IS:375.
- Busbar joints are bolted construction.
- CU/AL/GI horizontal earth bus of adequate size as required providing all along length of panels.
WIRING
- All vertical sections shall be wired to make the control scheme complete and wires can also be provided for control wiring as per customer’s specification. The wire shall be conformed to IS:694.
- The control wiring shall be of 1000 V grade PVC insulated standard copper wire and also to be provided for control wiring as per color customer’s specification. The wire shall be conformed to IS:694.
- Each control wire shall have ferrules at both ends as per control scheme.
- Not more than tow wires shall be connected to one terminal.
- Power control wires shall be nearly bunched separately and adequately supported so as to prevent stresses and strain on termination.
- Power control wires shall be nearly stressed and strained on termination.
CABLE
- Cable entry may be from top/bottom removable gland plates of 2mm or 3mm thickness shall be provided for drilling holes at site.
- Power terminals for cables shall be completed with crimping type lugs.
- For incoming feeders rated minimum 200A and above or where cable sizes are large, the cable termination shall be done through adequate size of bus for proper termination.